San Juan Bautista, California
City of San Juan Bautista Ordinance No. 2021-06 (adopted April 20, 2021), now Chapter 5-36 Water Softeners, prohibits installing a residential brine discharging water softening or conditioning appliance that discharges to the POTW, a tributary sewer, or land in the city. That is a city sewer/POTW rule — not a statewide ban. The 2024 CCR prints hardness from city wells as one number, 397 mg/L.
- Hardness397 mg/L (range 377–417)
- Residual chlorine0.95 mg/L (range 0.3–1.6)
- Nitrate as N1.4 mg/L (range <0.1–2.7)
- Arsenic1.6 µg/L (range <1–2.1)
- Iron (treated)31 µg/L (range <30–39)
On the report
- Water utility
- City of San Juan Bautista Water System
- Hardness
- 397 mg/L as CaCO3 (range 377–417), sampled 2023, City of San Juan Bautista 2024 Consumer Confidence Report. Grains are not printed. This is the city well table, not a blended West Hills number. — City of San Juan Bautista 2024 Consumer Confidence Report
- Disinfectant
- Residual chlorine (field) 0.95 mg/L (range 0.3–1.6), monthly, 2024 CCR. Chlorine, not chloramine. — City of San Juan Bautista 2024 Consumer Confidence Report
- Sanitation district
- City of San Juan Bautista (POTW / sewer)
- Brine / salt to the sewer
- Self-regenerating salt softeners prohibited (district rule). Ordinance No. 2021-06 (adopted April 20, 2021), added as Title 5 Section 35 and now Chapter 5-36, § 5-36-040 (PDF § 5-35-040) says no person shall install or assist in installing a residential brine discharging water softening or conditioning appliance that discharges into the POTW, a private or community sewer tributary to the POTW, or land within the city. Violation is a fine up to $1,000 and a public nuisance (civil action or Chapter 2-7 citations). Existing self-regenerating units that discharge to the POTW must be removed on or about the date the West Hills potable supply is connected, installed, and fully functional; the city notifies residents of that date (§ 5-36-060 / PDF § 5-35-060). Findings (Q) name portable-exchange tanks regenerated off-site outside the city as remaining legal alternatives that do not discharge brine to the POTW. The City Manager may grant a medical exemption only if § 5-36-080(A)–(C) are all met. Drivers in the findings include Central Coast Order R3-2009-0019 / NPDES CA0047902, EPA AOC Docket CWA-309(a)-20-007, and Central Coast Resolution R3-2011-0215 — not a statewide ban. Ask Public Works or the agency on the sewer bill about the address.
Also around here
Extra context besides the utility report and the chart above — geology, an unregulated table, or a published study. Not a second set of printed tap numbers.
- MicroplasticsWHO’s 2019 review examined studies that found microplastic particles in treated tap and bottled water in many places. That is a published-occurrence finding, not a number from this city’s water-quality report, and we do not invent a particles-per-liter count for the tap.Microplastics in drinking-water — World Health Organization
- Iron and manganese (raw vs treated)The 2024 CCR prints raw quarterly Well 5 numbers above the secondary MCLs and treated monthly numbers after the iron/manganese system. Those are two printed columns on the same table, not a blended tap average we invented.Iron raw quarterly avg 1403 µg/L (1160–1950), treated monthly avg 31 (<30–39), secondary MCL 300. Manganese raw quarterly avg 248 µg/L (239–258), treated monthly <15, secondary MCL 50.2024 Consumer Confidence Report (PWS ID CA3510002) — City of San Juan Bautista Water System / State Water Board
- Other printed inorganicsThe same 2024 CCR table prints sodium, chloride, TDS, and total chromium. Hexavalent chromium is not a row on that report.Sodium 69 mg/L (range 53–85), 2023. Chloride 79.4 mg/L (range 57.8–101), 2023. TDS 603 mg/L (range 588–618), 2023. Total chromium 2.1 µg/L (range 1.9–2.3), MCL 50, 2023.2024 Consumer Confidence Report (PWS ID CA3510002) — City of San Juan Bautista Water System / State Water Board
- Disinfection byproductsTable 7 of the 2024 CCR prints TTHMs and HAA5 from the August 22, 2024 sample.TTHMs 24.5 µg/L (range <1–25). HAA5 <6 µg/L (range <1–4).2024 Consumer Confidence Report (PWS ID CA3510002) — City of San Juan Bautista Water System / State Water Board
- PFAS and chromium-6The 2024 CCR tables we opened do not print a PFAS row and do not print a hexavalent chromium row. This file does not invent either number.2024 Consumer Confidence Report (PWS ID CA3510002) — City of San Juan Bautista Water System / State Water Board
San Juan Bautista’s rule is a city sewer / POTW ordinance, not a statewide salt-softener ban. Ordinance No. 2021-06 (introduced March 16, 2021; adopted April 20, 2021) added Section 35 to Title 5. The code reviser later numbered it Chapter 5-36 Water Softeners so it would not collide with another Chapter 5-35. Ask Public Works or the agency on the sewer bill about the address.
§ 5-36-040 (PDF § 5-35-040): no person shall install or in any manner assist in installing a residential brine discharging water softening or conditioning appliance that discharges into the POTW, into a private or community sewer tributary to the POTW, or to land within the city. Violation is a fine not to exceed $1,000 and a public nuisance. § 5-36-060 (PDF § 5-35-060): owners must remove existing self-regenerating units that discharge to the POTW on or about the date the West Hills potable water supply is connected, installed, and fully functional; the city notifies residents of that date; tenants must notify owners. Findings (Q) say residents may still soften or condition with appliances that do not discharge brine to the POTW, and name portable-exchange tanks regenerated off-site outside the city. § 5-36-080 lets the City Manager grant a medical exemption only if (A) the application is approved, (B) a physician verifies in writing a medical need for soft water, and (C) finances preclude a non-brine alternative; the exemption may be rescinded with 60 days’ notice. We do not invent another exception.
The findings cite Central Coast Regional Board Order R3-2009-0019 / NPDES CA0047902, EPA Administrative Order on Consent Docket CWA-309(a)-20-007 (August 18, 2020), and Central Coast Resolution R3-2011-0215 (December 1, 2011) finding residential self-regenerating softeners a significant controllable salt source in San Benito County. Those are the drivers in the findings. The ban itself is the city ordinance.
Drinking water is the City of San Juan Bautista Water System, PWS CA3510002, groundwater wells 1, 5, and 6 near the south end of the city (2024 Consumer Confidence Report, report date June 6, 2025). Hardness 397 mg/L as CaCO3 (range 377–417), sampled 2023. Residual chlorine 0.95 mg/L (range 0.3–1.6), monthly field samples. Nitrate as N 1.4 mg/L (range <0.1–2.7), MCL 10, 2024. Arsenic 1.6 µg/L (range <1–2.1), MCL 10, 2023. Total chromium 2.1 µg/L (range 1.9–2.3), MCL 50, 2023. Chloride 79.4 mg/L (range 57.8–101), 2023. TDS 603 mg/L (range 588–618), 2023. Sodium 69 mg/L (range 53–85), 2023. Iron: raw quarterly 1403 µg/L (1160–1950), treated monthly 31 µg/L (<30–39), secondary MCL 300. Manganese: raw quarterly 248 µg/L (239–258), treated monthly <15, secondary MCL 50. TTHMs 24.5 µg/L (<1–25) sampled August 22, 2024; HAA5 <6. The 2024 CCR does not print a hexavalent chromium row or a PFAS row. This file does not invent either. Kitchen shopping stays the Cloud RO / Waterdrop path already used on other cities if a listing is why you are looking.
What actually fits
Some links are affiliate links. If you buy through one, we may earn a commission. That does not change the match, and it is not a medical claim.
As an Amazon Associate we earn from qualifying purchases.
If you want actual soft water
Portable-exchange tanks, if that exception applies at your address. The resin still removes hardness. The salt work happens off site. Do not install a self-regenerating unit to the sewer here.
If you only want less scale and you hate salt bags

A salt-free conditioner changes how scale sticks. It does not soften. Soap and spots stay closer to untreated. No brine line.
If the shower just smells like the pool

That is chlorine. A whole-house carbon filter with an NSF/ANSI 42 chlorine claim is the usual match. A softener will not take chlorine out.
If you are shopping a PFAS listing for the kitchen

The under-sink RO we actually run is Cloud RO — NSF/ANSI 58, kitchen tap, not a whole-house tank. Check the exact listing if PFAS is why you are shopping. Waterdrop is a tankless option if you want that path. A certifier-listed pitcher is the cheap first step. Nobody is paying for a medical claim.
Shop Cloud ROShop Waterdrop reverse osmosisShop PFAS-listed pitchers
If you have not tested the tap
A homeowner kit is a start. It is not a state-certified lab. Use a certified lab when the decision is expensive.
Sources
- Ordinance No. 2021-06, adding Section 35 to Title 5 (Water Softeners) — City of San Juan Bautista. Accessed 2026-09-03.
- Chapter 5-36 Water Softeners (Ord. 2021-06; editorially renumbered from 5-35) — City of San Juan Bautista Municipal Code (Code Publishing / eCode360 SA4622). Accessed 2026-09-03.
- 2024 Consumer Confidence Report (PWS ID CA3510002) — City of San Juan Bautista Water System / State Water Board. Accessed 2026-09-03.
Updated September 3, 2026. A city file is chemistry we can cite plus the sewer rule. No invented detections.